Professional chimney service

Repairs Inside the Opening You Sit In Front Of

Tell Us What It Is Doing

Gas Hearth Focus
Meter-Tested Parts
Written Price Before Work
Photos in Every Report
NFPA 211 Inspection Levels
Based in La Habra Heights
Gas Hearth Focus
Meter-Tested Parts
Written Price Before Work
Photos in Every Report
NFPA 211 Inspection Levels
Based in La Habra Heights

The Work, Part by Part

The box around the flame takes the heat every time it runs. In masonry fireplaces we cut out cracked firebrick, relay it in refractory mortar and repair the hearth in front. In factory-built units we fit refractory panels, door latches, screens and grates from the maker's parts list. If a panel has gone out of production, you hear that before anything is ordered, along with a price for an option that is still made.

Firebrick relaid in refractory mortar
Refractory panels for factory-built units
Door latches, screens and grates renewed
Hearth cracks in front of the opening repaired
Alternatives priced when a panel is out of production

The Firebox Takes the Heat So the House Does Not

Whatever burns in it, a fireplace depends on its lining. In a masonry fireplace that lining is firebrick set in thin refractory joints. In a factory-built unit it is a set of molded refractory panels, back and sides and sometimes a floor, fitted inside a steel box. In a sealed gas unit it is often a ceramic fiber liner shaped to look like brick. Each of these exists to keep flame and heat away from the steel, framing and drywall behind them, and each one wears. Firebrick joints open and bricks crack. Molded panels craze, then split, then let a gap open to the steel. Fiber liners crumble at the edges where logs touch them. In La Habra Heights we see a lot of factory-built boxes from the decades when tract building was at its peak, and many have panels on their second or third cracked winter. We replace them with parts matched to the maker and model where those parts still exist.

Doors, screens and glass are the other half of most fireplace repair calls. Bifold glass doors lose their hinges, their tracks bend, and the gasket that seals the frame to the opening drops out. Mesh screens tear or come off their rods. On sealed gas units the front glass is a structural part of the system, held to a gasket that keeps the firebox closed off from the room, so a crack or a perished gasket means the unit should not run until it is fixed. We stock common gaskets and order glass and panels by model. Price depends on what is broken and whether the maker still supplies the part, so we write a scope after seeing the fireplace. When parts are gone, we tell you what the options are: a compatible substitute where one is approved, or a replacement unit where it is not.

When a Repair Turns Into a Rethink

Some fireplaces reach a point where fixing them piece by piece stops making sense. A factory-built box whose steel walls have rusted through, or whose maker no longer supplies panels or doors, cannot be put right with substitutes, because the whole unit was tested as one. A masonry firebox with crumbling joints all round may be better rebuilt than patched. At that stage owners in Whittier and Diamond Bar ask about going to gas, and it is our favorite conversation. A gas insert can go into a sound masonry opening with a liner run up the existing flue. A worn-out factory box can sometimes be replaced with a new unit sized to the same framing. We lay out what each route involves and roughly what it costs from our published figures, so you can compare repair against replacement without feeling pushed toward either.

A few observations from you speed things up. Look at the back and side walls of the firebox with a flashlight and tell us if you can see cracks, gaps or bare metal. Note whether the doors close properly and whether the glass is clear. If it is a gas unit, check the rating plate, usually behind the lower grille or under the firebox, and pass along the maker and model if you can read them, since that tells us which parts to look up before we arrive. Describe all of it on the contact page. We will confirm what the visit is for and roughly what to expect. Work begins only after you have the written price, and if the safer answer turns out to be replacement rather than repair, we tell you that plainly rather than selling you a part that will not last.

What Stays the Same on Every Job

Inspection Levels

NFPA 211 level picked to match why you called

Meter First

Gas parts measured before anything is swapped

Written Price

Parts, labor and total agreed before an order

Photos Kept

Pictures of each finding go in the report

Other Services

Chimney Sweep

Old creosote brushed from wood and gas flues, with the log set lifted out first and the cap and damper noted afterward.

Open →

Chimney Inspection

Inspections at the three NFPA 211 levels, with each gas appliance's vent, its size and any shared flue written up separately.

Open →

Chimney Repair

Damage to the stack, flue tile, cap and roof joint repaired once we know where the trouble starts, with a written scope you approve.

Open →

Fireplace Inspection

The room side of the hearth looked over part by part: firebox panels, glass and seal, burner, valve compartment and the mantel clearance.

Open →

Chimney Level 2 Inspection

Recorded footage from firebox to cap plus attic and roof checks, booked when a house sells, the fuel changes or the ground has shaken.

Open →

Chimney Cap Installation

A cap fitted to the flue or vent termination so rain, birds and gusts stay out of the pipe your pilot depends on.

Open →

Chimney Flashing Repair

The roof joint around the stack resealed with new step and counter pieces, so winter storms stop reaching the firebox below.

Open →

Chimney Masonry Repair

Open joints, flaking brick faces and loose top courses repaired, with the mortar mix picked after testing what is already in the wall.

Open →

Chimney Rebuilds

Stacks too loose to repair taken down and relaid, with a liner sized for the gas or wood appliance that will use them.

Open →

Fireplace Cleaning

Ash, soot and stains cleared from the firebox and the face around it, with doors, screen and grate cleaned and looked over.

Open →

Gas Fireplace Cleaning

Annual gas fireplace visit: burner ports, pilot hood, ember bed and glass cleaned, then the flame and room air read on relight.

Open →

Gas Fireplace Repair

Dropping pilots, igniters that spark without lighting, dead remotes and weak flames traced with a meter to the failed part.

Open →

Fireplace Remodel

A new face, hearth or mantel built around a gas or wood fireplace, with the unit's clearances measured before any design starts.

Open →

Fireplace Inserts

Gas, wood or electric inserts set into an existing masonry opening, with a new liner to the top for gas and wood models.

Open →

Pellet Stove Repair

Error codes, cold starts and smoky burns on pellet stoves traced with a meter, plus the vent pipe brushed and resealed.

Open →

Wood Stove Repair

Door gaskets, firebrick, baffles, glass and catalysts renewed on wood stoves, with the connector pipe and hearth pad looked over.

Open →

Gas Logs

Ceramic log sets and burners fitted to masonry fireplaces, chosen for the opening, the room and the flue they will vent through.

Open →

Chimney Seismic Retrofit

Brick chimneys at risk in a strong quake braced, strapped or rebuilt lighter above the roof, with the options compared in writing.

Open →

Chimney Crown Repair

Cracked or crumbling chimney tops repaired, either by sealing fine cracks or casting a fresh top with a lip that sheds water.

Open →

Dryer Vent Cleaning

Lint cleared from the duct between a gas or electric dryer and the outside hood, with the hood flap and transition hose looked over.

Open →

Chimney Liner Installation

Stainless or aluminum liners fitted inside old flues so a gas insert, log set or water heater vents at the right size.

Open →

Chimney Leak Repair

Water traced from the stain inside back to where it enters, then sealed at that source, whether metal, masonry or the top.

Open →

Chimney Waterproofing

A breathable silane or siloxane treatment brushed onto porous brick after joints and the top are repaired, so storms soak in less.

Open →

Chimney Damper Repair

Seized, rusted or warped dampers freed, rebuilt or replaced, including the stop that holds a damper open above a gas log set.

Open →

Chimney Chase Cover

Rusted or dished metal lids on framed chimneys replaced with a custom-bent stainless lid that sheds water off every edge.

Open →
Call (562) 449-0443