Professional chimney service

Wood Stoves That Burn Slowly Again

Tell Us What It Is Doing

Gas Hearth Focus
Meter-Tested Parts
Written Price Before Work
Photos in Every Report
NFPA 211 Inspection Levels
Based in La Habra Heights
Gas Hearth Focus
Meter-Tested Parts
Written Price Before Work
Photos in Every Report
NFPA 211 Inspection Levels
Based in La Habra Heights

The Work, Part by Part

Wood stoves wear out in predictable places. Gaskets go hard and stop sealing, so the fire runs hot and eats fuel. Firebrick splits, baffles warp and catalysts clog. We order parts for your stove's model, fit them, and test the door seal with a strip of paper. Then we look at the pipe joining stove to chimney, the hearth pad underneath and the distances to nearby walls.

Door seal tested with a paper strip
Split firebrick swapped in the stove body
Warped baffles and clogged catalysts replaced
Parts ordered by stove model
Connector pipe and hearth pad looked over

What Wears Out Inside a Stove

Turning the air lever on a stove is meant to slow the fire or wake it up. That lever only means something if every other seam on the box is tight. Woven fiberglass rope is the seal that fails soonest: a few winters of heat turn it stiff and thin, and air leaks in past it. The stove then burns hot no matter where the control sits, eats wood quickly and can overheat. Inside, firebrick lines the floor and walls, and those bricks crack with time. Above the fire, a baffle or a row of air tubes holds the smoke in the hot zone a little longer so more of it burns; on newer stoves those parts are steel or ceramic board and they warp, crack or sag. Panes break as well, usually after a knock from a split log or a sudden chill. Each of these parts is made for the model, and we order by maker and model number.

On a repair visit we start by closing the stove and checking the door seal with a strip of paper at several points round the frame; if it slides out with no drag, the gasket has gone. We look at the glass, the firebrick and the baffle, run the air control through its range, and check the stovepipe joints and the connection to the chimney or the wall thimble. Then we replace what has worn, with high temperature cement where the maker calls for it, and light a small fire to confirm the stove holds its seal and the control responds. Prices depend on the parts and how much of the stove has to come apart, and we name them before work starts. If the stove body itself is cracked or warped, we say so, since a cracked firebox cannot be sealed by new gaskets.

Wood Stoves, Burn Rules and the Gas Question

Wood stoves are a minority in La Habra Heights, and the owners who keep them usually love them: a steady fire on a winter night in a hillside house is hard to beat. They also live under the same air district rules as any wood burner. South Coast AQMD Rule 445 limits wood burning on certain winter days, which means a wood stove can sit cold on the nights you most want it. Some owners keep the stove and accept that. Others ask us about gas. A gas stove looks very much like a wood one, with a cast iron or steel body and a glass front, but it burns a log set behind the glass, lights with a switch or remote and is not restricted on those days. It can often use the same vent route with a new liner or a direct vent kit. We are glad to talk through either path.

The stovepipe and chimney need as much care as the stove. A stove that runs too cool, starved of air for long overnight burns, deposits creosote in the pipe and flue quickly, and a stove that has been leaking air may have been running hot enough to stress the pipe joints. On a repair visit we check both, and if the flue has not been swept this season we suggest doing it on the same trip. When you contact us, read us the name cast into the door or printed on the back label, what it is doing that worries you, and how it vents: straight up through the ceiling, out through a wall, or into a brick chimney. We will bring the gaskets and cement likely to be needed, and you get the price for anything else before we order it.

What Stays the Same on Every Job

Inspection Levels

NFPA 211 level picked to match why you called

Meter First

Gas parts measured before anything is swapped

Written Price

Parts, labor and total agreed before an order

Photos Kept

Pictures of each finding go in the report

Other Services

Chimney Sweep

Old creosote brushed from wood and gas flues, with the log set lifted out first and the cap and damper noted afterward.

Open →

Chimney Inspection

Inspections at the three NFPA 211 levels, with each gas appliance's vent, its size and any shared flue written up separately.

Open →

Chimney Repair

Damage to the stack, flue tile, cap and roof joint repaired once we know where the trouble starts, with a written scope you approve.

Open →

Fireplace Inspection

The room side of the hearth looked over part by part: firebox panels, glass and seal, burner, valve compartment and the mantel clearance.

Open →

Fireplace Repair

Cracked firebrick, warped refractory panels, broken doors and screens repaired in masonry and factory-built fireboxes, using maker's parts where they exist.

Open →

Chimney Level 2 Inspection

Recorded footage from firebox to cap plus attic and roof checks, booked when a house sells, the fuel changes or the ground has shaken.

Open →

Chimney Cap Installation

A cap fitted to the flue or vent termination so rain, birds and gusts stay out of the pipe your pilot depends on.

Open →

Chimney Flashing Repair

The roof joint around the stack resealed with new step and counter pieces, so winter storms stop reaching the firebox below.

Open →

Chimney Masonry Repair

Open joints, flaking brick faces and loose top courses repaired, with the mortar mix picked after testing what is already in the wall.

Open →

Chimney Rebuilds

Stacks too loose to repair taken down and relaid, with a liner sized for the gas or wood appliance that will use them.

Open →

Fireplace Cleaning

Ash, soot and stains cleared from the firebox and the face around it, with doors, screen and grate cleaned and looked over.

Open →

Gas Fireplace Cleaning

Annual gas fireplace visit: burner ports, pilot hood, ember bed and glass cleaned, then the flame and room air read on relight.

Open →

Gas Fireplace Repair

Dropping pilots, igniters that spark without lighting, dead remotes and weak flames traced with a meter to the failed part.

Open →

Fireplace Remodel

A new face, hearth or mantel built around a gas or wood fireplace, with the unit's clearances measured before any design starts.

Open →

Fireplace Inserts

Gas, wood or electric inserts set into an existing masonry opening, with a new liner to the top for gas and wood models.

Open →

Pellet Stove Repair

Error codes, cold starts and smoky burns on pellet stoves traced with a meter, plus the vent pipe brushed and resealed.

Open →

Gas Logs

Ceramic log sets and burners fitted to masonry fireplaces, chosen for the opening, the room and the flue they will vent through.

Open →

Chimney Seismic Retrofit

Brick chimneys at risk in a strong quake braced, strapped or rebuilt lighter above the roof, with the options compared in writing.

Open →

Chimney Crown Repair

Cracked or crumbling chimney tops repaired, either by sealing fine cracks or casting a fresh top with a lip that sheds water.

Open →

Dryer Vent Cleaning

Lint cleared from the duct between a gas or electric dryer and the outside hood, with the hood flap and transition hose looked over.

Open →

Chimney Liner Installation

Stainless or aluminum liners fitted inside old flues so a gas insert, log set or water heater vents at the right size.

Open →

Chimney Leak Repair

Water traced from the stain inside back to where it enters, then sealed at that source, whether metal, masonry or the top.

Open →

Chimney Waterproofing

A breathable silane or siloxane treatment brushed onto porous brick after joints and the top are repaired, so storms soak in less.

Open →

Chimney Damper Repair

Seized, rusted or warped dampers freed, rebuilt or replaced, including the stop that holds a damper open above a gas log set.

Open →

Chimney Chase Cover

Rusted or dished metal lids on framed chimneys replaced with a custom-bent stainless lid that sheds water off every edge.

Open →
Call (562) 449-0443