A Liner Matched to the Gas Appliance Below It
Tell Us What It Is Doing
A line on the symptom and the address is enough. We reply with a visit day and the parts we expect to bring.
The Work, Part by Part
Gas exhaust is cooler and wetter than wood smoke, and in an oversized clay flue it condenses, eats mortar and drafts poorly. A liner matched to the appliance fixes that. We measure the flue from the roof, choose the diameter from the appliance's specifications, and connect it at the bottom to the unit or its adapter. Cracked clay tile from a quake or a chimney fire is the other common reason to reline.
Why Gas Exhaust Needs Its Own Lining
A brick chimney built for an open wood fire has a large flue, often eight by twelve inches or bigger, lined with clay tile. Wood smoke filled that space easily. A gas appliance makes far less exhaust and at a lower temperature, so in a large flue its gases spread out, slow down and cool. Cool exhaust holds less water, and the water condenses on the tile. Over years that moisture erodes mortar joints, flakes the tile surface and soaks into the brick. A flue that is too large can also draft poorly for a gas appliance, letting exhaust linger near the opening. A stainless liner fixes both problems. It is a smooth tube, sized to the appliance's vent outlet, running the full height of the chimney inside the old flue. The exhaust stays warm and moves fast, condensation runs down a surface built to handle it, and the masonry around it stays dry.
The type of liner depends on what sits at the bottom. A vented gas log set in an open firebox usually relies on the existing flue if it is sound, but a cracked flue gets a liner sized to the set's burner. A direct vent gas insert needs two passages, one bringing outside air down to the burner and one carrying exhaust up. That is done with two flexible liners side by side, called co-linear, or one inside the other, called coaxial, and the insert maker specifies which. A gas furnace or water heater sharing the chimney needs its own properly sized vent as well. Before any of this, we look at the flue with a camera or a Level 2 inspection at $415 if it has not been seen recently, because we need to know about offsets, damaged tile and obstructions that affect how the liner is fed in.
What the Liner Quote Includes
Relining is mostly done from the roof. We brush the old tile, take out whatever damper hardware blocks the throat, and feed the stainless tube through the chimney to the appliance. At the bottom it connects to the insert or to an adapter on the log set's flue collar. Up top, a steel plate bolted across the old tile closes the space beside the tube, and a rain cap crowns the run. On chimneys that run close to wood framing, the liner may need an insulation wrap to keep its outside cool enough; the manufacturer's instructions and the chimney's clearances decide that. The quote lists each part: the liner type and length, any insulation, the top plate and cap, connectors, and any work needed on the crown or damper to make room. It also explains what will happen if the flue turns out to have an offset or blockage the camera could not see past.
Cost follows the run length, the tube diameter and alloy, single or paired tubes, and roof pitch. When a liner goes in as part of a gas insert installation, it is included in our published insert range of $2,950 to $5,950. On its own, for a log set, a furnace or a cracked flue, it is priced after we have looked. Many older chimneys in Whittier and La Habra Heights need a liner when the owner converts to gas, and it is better to know before the insert is chosen, since the insert dictates the liner size. On the contact page, list the appliance at the base of the chimney today, the one you are considering, the age of the house if you know it, and any mention of cracked tile in past reports.
What Stays the Same on Every Job
Inspection Levels
NFPA 211 level picked to match why you called
Meter First
Gas parts measured before anything is swapped
Written Price
Parts, labor and total agreed before an order
Photos Kept
Pictures of each finding go in the report
Where we book chimney liner installation
Open a city for local house types, weather notes and ZIP codes alongside this service.
Nothing on the route under that name. Search a ZIP code or open the areas page.
Other Services
Chimney Sweep
Old creosote brushed from wood and gas flues, with the log set lifted out first and the cap and damper noted afterward.
Open →Chimney Inspection
Inspections at the three NFPA 211 levels, with each gas appliance's vent, its size and any shared flue written up separately.
Open →Chimney Repair
Damage to the stack, flue tile, cap and roof joint repaired once we know where the trouble starts, with a written scope you approve.
Open →Fireplace Inspection
The room side of the hearth looked over part by part: firebox panels, glass and seal, burner, valve compartment and the mantel clearance.
Open →Fireplace Repair
Cracked firebrick, warped refractory panels, broken doors and screens repaired in masonry and factory-built fireboxes, using maker's parts where they exist.
Open →Chimney Level 2 Inspection
Recorded footage from firebox to cap plus attic and roof checks, booked when a house sells, the fuel changes or the ground has shaken.
Open →Chimney Cap Installation
A cap fitted to the flue or vent termination so rain, birds and gusts stay out of the pipe your pilot depends on.
Open →Chimney Flashing Repair
The roof joint around the stack resealed with new step and counter pieces, so winter storms stop reaching the firebox below.
Open →Chimney Masonry Repair
Open joints, flaking brick faces and loose top courses repaired, with the mortar mix picked after testing what is already in the wall.
Open →Chimney Rebuilds
Stacks too loose to repair taken down and relaid, with a liner sized for the gas or wood appliance that will use them.
Open →Fireplace Cleaning
Ash, soot and stains cleared from the firebox and the face around it, with doors, screen and grate cleaned and looked over.
Open →Gas Fireplace Cleaning
Annual gas fireplace visit: burner ports, pilot hood, ember bed and glass cleaned, then the flame and room air read on relight.
Open →Gas Fireplace Repair
Dropping pilots, igniters that spark without lighting, dead remotes and weak flames traced with a meter to the failed part.
Open →Fireplace Remodel
A new face, hearth or mantel built around a gas or wood fireplace, with the unit's clearances measured before any design starts.
Open →Fireplace Inserts
Gas, wood or electric inserts set into an existing masonry opening, with a new liner to the top for gas and wood models.
Open →Pellet Stove Repair
Error codes, cold starts and smoky burns on pellet stoves traced with a meter, plus the vent pipe brushed and resealed.
Open →Wood Stove Repair
Door gaskets, firebrick, baffles, glass and catalysts renewed on wood stoves, with the connector pipe and hearth pad looked over.
Open →Gas Logs
Ceramic log sets and burners fitted to masonry fireplaces, chosen for the opening, the room and the flue they will vent through.
Open →Chimney Seismic Retrofit
Brick chimneys at risk in a strong quake braced, strapped or rebuilt lighter above the roof, with the options compared in writing.
Open →Chimney Crown Repair
Cracked or crumbling chimney tops repaired, either by sealing fine cracks or casting a fresh top with a lip that sheds water.
Open →Dryer Vent Cleaning
Lint cleared from the duct between a gas or electric dryer and the outside hood, with the hood flap and transition hose looked over.
Open →Chimney Leak Repair
Water traced from the stain inside back to where it enters, then sealed at that source, whether metal, masonry or the top.
Open →Chimney Waterproofing
A breathable silane or siloxane treatment brushed onto porous brick after joints and the top are repaired, so storms soak in less.
Open →Chimney Damper Repair
Seized, rusted or warped dampers freed, rebuilt or replaced, including the stop that holds a damper open above a gas log set.
Open →Chimney Chase Cover
Rusted or dished metal lids on framed chimneys replaced with a custom-bent stainless lid that sheds water off every edge.
Open →