Choose the Burner First, Then the Stone
Tell Us What It Is Doing
A line on the symptom and the address is enough. We reply with a visit day and the parts we expect to bring.
The Work, Part by Part
Remodels usually start because the face looks dated, but on a gas fireplace the clearances decide what is possible. The maker's manual sets how close a mantel, shelf or combustible facing may sit, and a remodel that ignores it can scorch wood. We measure, look over the unit and the flue, then plan the new face in tile, stone, brick or plaster with those figures on the drawing. Converting to gas can be part of the same job.
Why the Appliance Comes Before the Finish
The phone call usually opens with something visual: brick painted over three times, a plain builder tile border, a mantel nobody likes. As a gas hearth shop we ask a different first question. What will burn in this fireplace once the work is done? If the answer is a gas insert or a new gas fireplace, the unit decides a great deal about the finished wall. Every gas appliance comes with a manual that sets minimum distances to anything that can burn, including the mantel, the side trim and the material on the face, plus the hearth depth in front of it. Some units allow tile or stone right up to the opening, others need a metal trim kit or a set gap. Picking a surround first and the unit second is how owners end up with a mantel that has to be moved or a beautiful stone face that blocks the access panel. We work the other way round.
In practice that means a visit to measure the opening and look at what is behind it: masonry, a factory-built box, a gas line or none, and the path the vent will take. From there we suggest units that fit, explain how each one looks and heats, and mark the clearances on a simple sketch so your choice of tile, stone or plaster can be made against real numbers. The remodel can be as light as a new face over an existing gas insert or as large as removing an old wood box and building a new wall around a direct vent unit. Whatever the size, the finished fireplace has to work as an appliance first. That is also why we test fire the unit before the last trim goes on, so any adjustment to the flame or the vent happens while access is still easy.
Remodels in Older and Newer Houses
The houses we work in shape the remodel. Older homes in Whittier and La Habra Heights often have a full masonry fireplace with a real brick chimney, and the most common plan there is a gas insert set into the existing firebox with a new face and mantel around it. The chimney gets a liner, and the old brick can be kept, refaced or plastered over. In the tract neighborhoods of Diamond Bar and Santa Fe Springs, factory-built metal fireplaces are the norm, and those boxes have a limited life. When one is worn out, the remodel often means taking it out and installing a new gas unit sized for the framing, then finishing the wall to suit. Each path has different costs, and our written plan breaks them into the appliance, the venting, the gas line work and the finish so you can see which parts drive the total.
The total rests on your choices and on whatever hides behind the old face, and the measuring visit ends in a written plan. For reference, our published range for converting a brick firebox with a sealed gas unit is $2,950 to $5,950 including the liner, and a direct vent fireplace in a spot that never had one is $4,750 to $9,500 before the finish work. Surround materials, mantels and any framing changes are added line by line. When you get in touch, tell us what the fireplace is now, how you want to use it once it is done, and any look you have admired in a magazine or a friend's house. We will set a visit to measure and talk through the choices, and nothing is ordered until you have read the plan and agreed to it.
What Stays the Same on Every Job
Inspection Levels
NFPA 211 level picked to match why you called
Meter First
Gas parts measured before anything is swapped
Written Price
Parts, labor and total agreed before an order
Photos Kept
Pictures of each finding go in the report
Where we book fireplace remodel
Open a city for local house types, weather notes and ZIP codes alongside this service.
CA
Fireplace Remodel in La Habra Heights
Home base for our gas hearth work: 96% of houses stand detached and 70% predate 1980. Pilot hood, thermocouple, shutoff valve: on a custom home of that age, those three get tested before the log set is lit.
Open city pageCA
Fireplace Remodel in Whittier
Older brick stacks here are often unreinforced or only lightly reinforced, and 88% of homes predate 1980. Gas logs or an insert set inside such brick still rely on a sound flue and a connector that holds gas, so we test both.
Open city pageCA
Fireplace Remodel in La Puente
81% of the housing predates 1980, raised where walnut orchards once stood. In a gas fireplace that old, thermocouple and pilot orifice wear thin, and replacing them is technician work.
Open city pageCA
Fireplace Remodel in Santa Fe Springs
Industry dominates, and homes sit in small pockets; just 5% predate 1950. On gas hearths of the 1950s and 1960s we leak-test the valve, clear clogged burner ports and judge the flame by its color.
Open city pageCA
Fireplace Remodel in Diamond Bar
77% owner-occupied, with 50% of houses older than 1980. A gas fireplace in one of them gets its glass seal, pilot assembly and outside vent termination looked over on our visit.
Open city pageOther Services
Chimney Sweep
Old creosote brushed from wood and gas flues, with the log set lifted out first and the cap and damper noted afterward.
Open →Chimney Inspection
Inspections at the three NFPA 211 levels, with each gas appliance's vent, its size and any shared flue written up separately.
Open →Chimney Repair
Damage to the stack, flue tile, cap and roof joint repaired once we know where the trouble starts, with a written scope you approve.
Open →Fireplace Inspection
The room side of the hearth looked over part by part: firebox panels, glass and seal, burner, valve compartment and the mantel clearance.
Open →Fireplace Repair
Cracked firebrick, warped refractory panels, broken doors and screens repaired in masonry and factory-built fireboxes, using maker's parts where they exist.
Open →Chimney Level 2 Inspection
Recorded footage from firebox to cap plus attic and roof checks, booked when a house sells, the fuel changes or the ground has shaken.
Open →Chimney Cap Installation
A cap fitted to the flue or vent termination so rain, birds and gusts stay out of the pipe your pilot depends on.
Open →Chimney Flashing Repair
The roof joint around the stack resealed with new step and counter pieces, so winter storms stop reaching the firebox below.
Open →Chimney Masonry Repair
Open joints, flaking brick faces and loose top courses repaired, with the mortar mix picked after testing what is already in the wall.
Open →Chimney Rebuilds
Stacks too loose to repair taken down and relaid, with a liner sized for the gas or wood appliance that will use them.
Open →Fireplace Cleaning
Ash, soot and stains cleared from the firebox and the face around it, with doors, screen and grate cleaned and looked over.
Open →Gas Fireplace Cleaning
Annual gas fireplace visit: burner ports, pilot hood, ember bed and glass cleaned, then the flame and room air read on relight.
Open →Gas Fireplace Repair
Dropping pilots, igniters that spark without lighting, dead remotes and weak flames traced with a meter to the failed part.
Open →Fireplace Inserts
Gas, wood or electric inserts set into an existing masonry opening, with a new liner to the top for gas and wood models.
Open →Pellet Stove Repair
Error codes, cold starts and smoky burns on pellet stoves traced with a meter, plus the vent pipe brushed and resealed.
Open →Wood Stove Repair
Door gaskets, firebrick, baffles, glass and catalysts renewed on wood stoves, with the connector pipe and hearth pad looked over.
Open →Gas Logs
Ceramic log sets and burners fitted to masonry fireplaces, chosen for the opening, the room and the flue they will vent through.
Open →Chimney Seismic Retrofit
Brick chimneys at risk in a strong quake braced, strapped or rebuilt lighter above the roof, with the options compared in writing.
Open →Chimney Crown Repair
Cracked or crumbling chimney tops repaired, either by sealing fine cracks or casting a fresh top with a lip that sheds water.
Open →Dryer Vent Cleaning
Lint cleared from the duct between a gas or electric dryer and the outside hood, with the hood flap and transition hose looked over.
Open →Chimney Liner Installation
Stainless or aluminum liners fitted inside old flues so a gas insert, log set or water heater vents at the right size.
Open →Chimney Leak Repair
Water traced from the stain inside back to where it enters, then sealed at that source, whether metal, masonry or the top.
Open →Chimney Waterproofing
A breathable silane or siloxane treatment brushed onto porous brick after joints and the top are repaired, so storms soak in less.
Open →Chimney Damper Repair
Seized, rusted or warped dampers freed, rebuilt or replaced, including the stop that holds a damper open above a gas log set.
Open →Chimney Chase Cover
Rusted or dished metal lids on framed chimneys replaced with a custom-bent stainless lid that sheds water off every edge.
Open →